New Ultra-compact Spider-20HE & Spider-20i with 256 kHz Sampling Rate

Download PDF | By Tim Hsiao - Senior Product Manager | © Copyright Crystal Instruments 2022, All Rights Reserved.

Featuring the highest sampling rate provided in the industry at 256 kHz. Handheld battery powered system with wired network options and 20 V input range. Sync between multiple devices. Choose the convenient portable model or industrial model for permanent mounting.


Featuring the highest sampling rate provided in the industry at 256 kHz. Handheld battery powered system with wired network options and 20 V input range. Sync between multiple devices. Choose the convenient portable model or industrial model for permanent mounting.

In June 2020 Crystal Instruments announced the release of EDM 9.0 and the Spider-20HE and Spider-20i, the newest editions of the Spider-20 series. These new models are designed for users requiring dynamic signal analyzers and recorders with uncompromising performance and portability.

The Spider-20HE and Spider-20i received a hardware upgrade to support an impressive 256 kHz sampling rate on all 4 input channels. It is the highest sampling rate offered in the market of compact analyzers. The high sampling rate is especially beneficial for measuring high orders and transient capture in blast tests, pyroshock events, drop shock tests, crash tests, etc.

In addition to the high sampling rate, the input range is expanded to 20 V to capture larger signals.

The battery power feature provides users with maximum portability. Besides a sensor cable, the analyzer can be moved around without an attached power source and computer.

The auto-wake feature provided in EDM 10.0 software allows users to set up a wake-up alarm for Spiders to power on, perform a test, and power off. Users can upload up to 8 predefined tests and run these in Black Box mode (without a connection to a computer or network to run). This convenient mode allows users to acquire data autonomously or with little user intervention.

EDM 10.0 also provides circular recording which allows the Spider units to constantly record all data, but save only the triggered events. In scenarios such as the recording of ground vibrations over a long period of time, enabling circular recording significantly reduces the amount of memory required to store data.

With IEEE 1588 support, the Spider-20HE and Spider-20i can synchronize with multiple devices to form a large channel system that can be distributed over the same network in a large space, such as an airplane or a large industrial plant.

The Spider-20i features a rugged industrial design, mounting holes, more robust and secure connectors, and a dust-proof, all aluminum chassis to facilitate heat dissipation. Without a battery included, the system is lighter and smaller.

 
Spider-20 models with 256 kHz.png
 

With the combination of the above features, the Spider-20 and Spider-20i are the perfect solutions for many applications including:

Figure 3 Captured Images of the test structure

With the combination of the above features, the Spider-20HE and Spider-20i are the perfect solutions for many applications including:

  • Machinery Diagnosis

  • Machine/Process Monitoring

  • Modal Analysis

  • Vehicle Dynamics

  • Production Testing

  • Temporary Monitor

  • Acoustic Studies

  • Transient Capture

Components included in rockets and space vehicles are subject to severe shock vibrations. To ensure reliability during missions, testing is undertaken using controlled explosives. A high sampling rate data acquisition device to acquire data from the shock sensors can reliably measure the high frequency content during these tests.

Shock Response Spectrum (SRS) calculations need sampling rates that are at least 10 times the maximum frequency of interest. With a limitation of 102.4 kHz, frequencies of up to only 10 kHz can be analyzed. With the new generation of Spiders, the SRS spectrum for maximum frequencies of 25 kHz can be acquired and analyzed.

In addition, by capturing the data at the maximum possible sampling rate, all the time domain features are effectively captured and preserved. Users can process the acquired data in real time or post process with different settings to completely analyze the data.

References:
https://jscfeatures.jsc.nasa.gov/pages.ashx/383/Pyroshock

For more details regarding the complete system, view the brochure online at: https://www.crystalinstruments.com/spider-20-dynamic-signal-analyzer

 
Spider-20HE Spider-20i
Max Sampling Rate 256 khz
Analog Input Channels
Input Channels 4
Coupling AC, DC, IEPE (ICP®)
Input Dynamic Range 120 dBFS
Input Range ±0.2 V, ±2 V, ±20 V
Max Useful Bandwidth 115.2 kHz
Tachometer Input Channel 1
Connector Type Isolated BNC (shared with analog output)
Configuration Tachometer or output, selected by software
Shaft RPM Range 3/N ~ 300000/N RPM
Analog Output Channel
Output Channels 1
Output Range ±10 V
DC Power Input
Connector Type 4 pin LEMO connector (on rear panel) 3-pin DIN connector
Voltage 15 VDC (±10%) 12-24 VDC (±10%)
Indicating LEDs Power, start/stop, battery, and charging Power
Network Communication
Type 100Base-T, RJ45
Power Specifications
Power Supply Interchangeable battery with DC charger interface External DC power
Power Consumption Less than 6 W
Environmental Specifications
Dimension 135 x 109 x 32.5 mm 155 x 109.6 x 30.7 mm
Weight 0.56 kg 0.52 kg
On-board Flash Memory 4 GB